Rossmax Suction Pump V3 16LPM | Phlegm Suction

RM1,290.00

Target Group

Ideal for tracheostomized patients, minor surgical applications and post-operative therapy in home-care and hospital.

Product Registration / Notification

GB22360738918

  

Product Description

Rossmax Suction Pump V3, also known as an aspirator, is a type of medical device that is primarily used for removing obstructions — like mucus, saliva, blood, or secretions — from a person’s airway. When an individual is unable to clear secretions due to a lack of consciousness or an ongoing medical procedure, suction machines help them breathe by maintaining a clear airway.

Rossmax Suction Pump V3 is a combination of advanced engineering and modern design of oil-free lubrication suction device. Ideal for tracheostomized patients, minor surgical applications and post-operative therapy in home-care and hospital.

Highlight of Rossmax Suction Pump V3:

  • Comfortable – High performance pump delivers -550mmHg vacuum and 16 liter/min flow rate.
  • Triple Protection – Overflow valve plus anti-bacteria filter and fool-proof design that prevents back flow of fluid and airborne contaminants from entering the pump.
  • Convenient – Easy to store using tubing holder and accessory compartment.
  • Ergonomic – Comprehensive dashboard with ergonomic view angle ensures a smooth operation.

How to Use Suction Pump?

  • Firstly, Connect all tube as shown in picture below. Don’t misplace the tube.
  • Secondly, Connect cable.
  • Thirdly, Turn ON button
  • Fourthly, Connect catheter to the end of long tube.
  • Lastly, Regulate pressure. to decrease turn left, to increase power turn right. block the long tube to check the pressure gauge and turn the regulator until required pressure.
  • Remember, Empty bottle after every use to avoid overflow.

Click here to learn more about Suction Pump. 

How To Use

The device must be checked before each use in order to detect malfunctions and / or damage caused by transport and / or storage and do not connect to power if damage is apparent. Before each use, the accessories must be carefully inspected to ensure the absence of dust, incrustation, clots or liquid substances both inside the connecting tubing and the collection canister. Furthermore, they must be cleaned following the instructions rigorously. We recommend personal use of the accessories, the collection canister, the connecting tubing and antibacterial filter to prevent risk of contagious infection.
1. Assembling procedures
1-1. Connect one end of connecting silicone tubing (?8mm,14cm), with the antibacterial filter marked ?IN? side, to the VACUUM inlet of the collection canister marked in yellow
1-2. Connect the other end, with the antibacterial filter marked ?OUT? side, to the ?AIR INLET? connector of the suction unit marked in yellow.
1-3. Connect the connecting PVC tubing (?7mm,180cm) to the ?PATIENT? inlet of the collection canister.
1-4. Connect the AC adaptor with the AC adaptor jack on the right side of the unit.
Note:
1. Use only the authorized Rossmax AC adaptor with this aspirator.
2. Ensure that the FLUID SIDE or IN marker on the filter is on the side facing the collection canister and fit into the ?VACUUM? inlet. A wrong connection may cause immediate destruction in case of contact with sucked liquids.
2. Setup Before Use
2-1. Before each use, inspect the unit and accessories. If damaged, expired and/ or deteriorated, replace it at once.
2-2. Place the unit on a flat, horizontal surface.
2-3. Plug the AC adaptor into the socket.
2-4. Place the switch to the ?I? (ON) position.
2-5. Collapse the tubing with the antibacterial filter and check the vacuum gauge to test that the unit makes vacuum without any leakage and this level varies when the vacuum regulator is acted on.
2-6. Obstruct the connecting tubing and adjust the level of vacuum prescribed by the doctor in the vacuum gauge turning the vacuum flow adjustment knob/ vacuum regulator.
Note: The vacuum regulator can be used to set the level of vacuum required (mmHg/kPa). Turn the regulator clockwise, in the ?+? direction, to obtain a higher vacuum; or anticlockwise for a lower vacuum; these values can be read on the vacuum gauge.
Important: The vacuum values on the control decal are purely for guidance; always refer to the reading shown on the vacuum gauge.
Note: Gauge is for reference only. If the unit sustains a severe drop, accuracy of the gauge must be checked.
2-7. Place the switch to the ?O? (OFF) position.
Note:
1. The device is intended to be used on a flat, horizontal surface in order for the overflow valve to function correctly and prevent liquids from entering the suction pump. The device must be kept away from walls to allow for adequate engine cooling.
2. In case unit is dropped, always transport unit with vacuum regulator rotated fully clockwise.
3. Starting the Suction
3-1. Connect the suction catheter to the connecting PVC tubing (?7mm,180cm)
Note: suction catheter and manual regulator are not supplied by Rossmax.
3-2. Switch on the unit (ON/OFF switch)
3-3. Place your finger on the manual regulator to activate the suction, begin suction on the patient using the suction catheter. The unit is ready to put the suction catheter to the patient.
3-4. After application, switch off the device and remove the AC adaptor from the mains socket. Perform the cleaning operations as described in the ?cleaning, sanitization, disinfection ?paragraph.
Note: A 30-minute interval is recommended after each use. Do not operate the device continuously for more than 30 minutes for a single use without turning it off and following with a cooling period for at least 30 minutes.

Indication

Suction Pump

Categories

Rehab & Medical Supplies

Brand

Rossmax

Target Group

Ideal for tracheostomized patients, minor surgical applications and post-operative therapy in home-care and hospital.

Product Registration / Notification

GB22360738918

  
Product Description

Rossmax Suction Pump V3, also known as an aspirator, is a type of medical device that is primarily used for removing obstructions — like mucus, saliva, blood, or secretions — from a person’s airway. When an individual is unable to clear secretions due to a lack of consciousness or an ongoing medical procedure, suction machines help them breathe by maintaining a clear airway.

Rossmax Suction Pump V3 is a combination of advanced engineering and modern design of oil-free lubrication suction device. Ideal for tracheostomized patients, minor surgical applications and post-operative therapy in home-care and hospital.

Highlight of Rossmax Suction Pump V3:

  • Comfortable – High performance pump delivers -550mmHg vacuum and 16 liter/min flow rate.
  • Triple Protection – Overflow valve plus anti-bacteria filter and fool-proof design that prevents back flow of fluid and airborne contaminants from entering the pump.
  • Convenient – Easy to store using tubing holder and accessory compartment.
  • Ergonomic – Comprehensive dashboard with ergonomic view angle ensures a smooth operation.

How to Use Suction Pump?

  • Firstly, Connect all tube as shown in picture below. Don’t misplace the tube.
  • Secondly, Connect cable.
  • Thirdly, Turn ON button
  • Fourthly, Connect catheter to the end of long tube.
  • Lastly, Regulate pressure. to decrease turn left, to increase power turn right. block the long tube to check the pressure gauge and turn the regulator until required pressure.
  • Remember, Empty bottle after every use to avoid overflow.

Click here to learn more about Suction Pump. 

How To Use

The device must be checked before each use in order to detect malfunctions and / or damage caused by transport and / or storage and do not connect to power if damage is apparent. Before each use, the accessories must be carefully inspected to ensure the absence of dust, incrustation, clots or liquid substances both inside the connecting tubing and the collection canister. Furthermore, they must be cleaned following the instructions rigorously. We recommend personal use of the accessories, the collection canister, the connecting tubing and antibacterial filter to prevent risk of contagious infection.
1. Assembling procedures
1-1. Connect one end of connecting silicone tubing (?8mm,14cm), with the antibacterial filter marked ?IN? side, to the VACUUM inlet of the collection canister marked in yellow
1-2. Connect the other end, with the antibacterial filter marked ?OUT? side, to the ?AIR INLET? connector of the suction unit marked in yellow.
1-3. Connect the connecting PVC tubing (?7mm,180cm) to the ?PATIENT? inlet of the collection canister.
1-4. Connect the AC adaptor with the AC adaptor jack on the right side of the unit.
Note:
1. Use only the authorized Rossmax AC adaptor with this aspirator.
2. Ensure that the FLUID SIDE or IN marker on the filter is on the side facing the collection canister and fit into the ?VACUUM? inlet. A wrong connection may cause immediate destruction in case of contact with sucked liquids.
2. Setup Before Use
2-1. Before each use, inspect the unit and accessories. If damaged, expired and/ or deteriorated, replace it at once.
2-2. Place the unit on a flat, horizontal surface.
2-3. Plug the AC adaptor into the socket.
2-4. Place the switch to the ?I? (ON) position.
2-5. Collapse the tubing with the antibacterial filter and check the vacuum gauge to test that the unit makes vacuum without any leakage and this level varies when the vacuum regulator is acted on.
2-6. Obstruct the connecting tubing and adjust the level of vacuum prescribed by the doctor in the vacuum gauge turning the vacuum flow adjustment knob/ vacuum regulator.
Note: The vacuum regulator can be used to set the level of vacuum required (mmHg/kPa). Turn the regulator clockwise, in the ?+? direction, to obtain a higher vacuum; or anticlockwise for a lower vacuum; these values can be read on the vacuum gauge.
Important: The vacuum values on the control decal are purely for guidance; always refer to the reading shown on the vacuum gauge.
Note: Gauge is for reference only. If the unit sustains a severe drop, accuracy of the gauge must be checked.
2-7. Place the switch to the ?O? (OFF) position.
Note:
1. The device is intended to be used on a flat, horizontal surface in order for the overflow valve to function correctly and prevent liquids from entering the suction pump. The device must be kept away from walls to allow for adequate engine cooling.
2. In case unit is dropped, always transport unit with vacuum regulator rotated fully clockwise.
3. Starting the Suction
3-1. Connect the suction catheter to the connecting PVC tubing (?7mm,180cm)
Note: suction catheter and manual regulator are not supplied by Rossmax.
3-2. Switch on the unit (ON/OFF switch)
3-3. Place your finger on the manual regulator to activate the suction, begin suction on the patient using the suction catheter. The unit is ready to put the suction catheter to the patient.
3-4. After application, switch off the device and remove the AC adaptor from the mains socket. Perform the cleaning operations as described in the ?cleaning, sanitization, disinfection ?paragraph.
Note: A 30-minute interval is recommended after each use. Do not operate the device continuously for more than 30 minutes for a single use without turning it off and following with a cooling period for at least 30 minutes.

Reviews

There are no reviews yet.

Be the first to review “Rossmax Suction Pump V3 16LPM | Phlegm Suction”

Your email address will not be published. Required fields are marked *

Order Processing Time and Standard Shipping

Most orders are processed within 2 business days upon receiving the order. Orders placed before 1:00pm (GMT+8:00) should be received within 1-7 business days. Orders placed on Saturdays, Sundays or public holidays are handled on the Monday or the first working day after. (Working days exclude Saturdays, Sundays and public holidays). Order processing may take a longer time during peak or festive seasons. 

Please expect 2-5 working days for West Malaysia (Peninsular) and 5-10 working days for East Malaysia (Sabah/Sarawak) to receive the order once the shipment is out for delivery.

Any changes on delivery address is not allowed after payment is made.

There are times where order processing time will take longer than usual, such as Pre-Order items or hot selling items that may run out of stock. Should there be such a situation, Siang Pharmacy will contact you to on the soonest available date. If you do not agree to wait for the provided date, we reserve the right to cancel the order and refund to you. Please refer to the Refund Policy and Terms of Service for more details.

We will ensure that all products that are shipped have proper packaging but we do not warranty that damages or poor handling by third parties may occur during transit. The customer is responsible to inform us at 04-583 3000 upon receiving and inspecting the product. Kindly refer to the Refund Policy and Terms of Service for more details.

Delayed or Lost Orders

A parcel is considered lost after it has been in the postal system for a period of 15 business days. We cannot take responsibility for delays caused by courier services, especially during peak seasons or other unforeseen circumstances (such as natural disasters, pandemic, war, riot, state of emergency, movement control order or abrupt termination of the third party services). Although orders normally take much less time than that, we are unable to dispatch a replacement until this period of time has elapsed or unless the parcel has been confirmed as lost by the courier service. 

Wrong or Incomplete Address

If your package is returned to us due to an incorrect or incomplete address, you must pay all delivery cost to re-deliver your order to a corrected address. We are not responsible for the loss of your order if the address provided at checkout is incomplete or incorrect.

International or Overseas Shipping

We do not provide any delivery services beyond the borders of Malaysia. Any purchase to be delivered outside of Malaysia will only be delivered to you at a local address, the rest of the shipping arrangements will be the responsibility of the customer.

Shipping to East Malaysia is restricted to selected items, typically for items below a volumetric weight of 30kg. Should there be any special request, you may contact us at 011-21689983.

Shipping Costs

Please refer to the shipping fee calculated upon check out. Shipping costs are calculated based on the volumetric weight of each purchased product. Shipping costs may be waived or reduced during certain promotion periods, using voucher codes, discount codes or automatically adjusted based on certain criteria. Users of the site may have to login with a valid user account to enjoy such benefits. Siang Pharmacy reserves the right to update or amend any shipping costs at any time without prior notice.

 

*Free Pharmacy reserves the right to update, remove or amend any part of the Shipping policy at any time without prior notice.

RELATED PRODUCTS